Akron 627 4-Way Hydrant Valve

485030205 (PFP-20HPHND-2D) 4" inlet
https://www.wfrfire.com/web/image/product.template/8353/image_1920?unique=7be15cc

specify inlet and outlet sizes and threads


Features

4-Way Hydrant Valve features include:

  • Flow efficient 3.5" waterway
  • 75 psi maximum pressure differential during changeover
  • 300 psi maximum operating pressure
  • 1,000 GPM maximum flow when changing ball position

How it Works:

Step 1
Attach the 4-Way Hydrant Valve to the hydrant and forward lay to the engine at fire scene.

Step 2
Attach a hose from the 4-Way Hydrant Valve to the intake on the engine at the hydrant

Step 3
Attach a hose from the discharge on the engine at hydrant to the 4-Way Hydrant Valve inlet. Establish re-circulating flow at hydrant pressure.

Step 4
Rotate the handwheel on top of the 4-Way Hydrant Valve to introduce pressurized flow from the engine at the hydrant to the engine at the fire scene. Increase pressure on the pumper to increase flow as required.

* Hydrant Inlet only available in 4" - 5"

Specifications

  • 13.75'' x 13.75" (349 x 349 mm)
  • 42 lbs. (19 kg)
  • Inlet: 2.5'' - 5'' F (65-125 mm)
  • Outlet: 2.5'' - 5'' M (65-125 mm)
Product Image
Akron 627 4-Way Hydrant Valve