| SCBA |
|
Assembly is quick and easy, requiring no special tools. All necessary parts and hardware are included for the particular arrangement being ordered. To Assemble One Unit for Horizontal Placement:
|
| Item # | Description |
Yellow Part # |
Black Part # |
Part # |
Qty For Horizontal Holder |
Qty For Vertical Holder |
|
1 |
Box | 1090-000-110 | 1090-000-112 | 1 | 1 | |
| 2 |
Cradle - 5.3" to 5.6" |
1090-000-120 | 1090-000-122 | 1 | 2 | |
| 3 |
Cradle - 6.75" to 7.25" |
1090-000-125 | 1090-000-127 | 1 | 2 | |
| 4 |
Top |
1090-000-130 | 1090-000-132 | 1 | 1 | |
| 5 | Stop | 1090-000-155 | 1090-000-157 | 1 | 1 | |
| 6 | 10-24 x 3/8" hex head m/s | 9010-101906 | 4 | 4 | ||
| 7 | 10-24 x 5/8" hex head m/s | 9010-101910 | 10 | 12 | ||
| 8 | 10-24 hex head nut | 9114-201900 | 14 | 16 | ||
| 9 | #10 lock washer | 9114-201900 | 14 | 16 | ||
| 10 | Rubber bumper | 1090-000-150 | 2 | 0 | ||
| 11 | Reflective label (horizontal) | 1090-000-105 | 1 | 0 | ||
| 12 | Reflective label (vertical) | 1090-000-106 | 0 | 1 |
|
|
To Assemble in Series of 2 or More Units for Horizontal
Placement: Follow steps 1, 2 and 3 as above. If the racks are placed one above the other, only one Top Panel is needed per stack. See diagram. Bolt top Box to the open Box below. Now finish by bolting Top Panel to the top Box. If placed side by side, bolt one Box to the other using 4 bolts. Use cradle bolts on the bottom of each Box and opposing holes at top for this purpose. |
|
|
To Assemble for Vertical Placement: For use in upright position 2 cradles must be used in each Box. Bumpers are not necessary.
|
| To use in series of 2 or more, bolt closed side of Box and cradle to open top of Box and cradle of preceding rack. Only one Top Panel is necessary for the open top of Box of the last rack in series. See Diagram. | |
|
|
New restraint strap prevents accidental release of SCBA air
cylinder, while providing immediate access when needed. NFPA 1901-96
Section 13-5.5 & 13-5.6 require restraint straps for SCBA air cylinder
storage racks. The straps are designed to keep the air cylinder in place
in the event of an accident or roll-over. The strap assembly bolts into
place utilizing the four corner mounting holes. Order with new storage
racks or retrofit onto existing units. Use with Model ACSR horizontal or
model VACSR vertical storage racks. Mounting Instructions:
|
|||||||||||||||
![]() |
|
![]() |
Copyright © WFR Wholesale Fire & Rescue Ltd. |