Home Catalogue Contact List Events Calendar HotShots Related Links Used Equipment
MSDS INDEX

DSL-100 All Synthetic Compressor Oil
1. PRODUCT IDENTIFICATION
   
Trade Name: DSL-100 Synthetic Ester
Chief Constituent:: Synthetic Esters (CAS #68515-59-1, 68515-47-9)
Hazardous Ingredients: None
Carcinogenic Ingredients: None
Company Information:: Summit Industrial Products Inc.
9010 CR 2120
Tyler, TX 75707
Phone: (903)534-8021

 

2. WARNING STATEMENTS
 

None

 

3. PHYSICAL and CHEMICAL DATA
   
Odour & Appearance: Bright and clear, mild odour
Specific Gravity: <1.0
Boiling Point: >600°F
Vapour Density: <.035 mm Hg @ 300°F

 

4. FIRE PROTECTION
   
Flash Point: >450°F
Extinguishing Media: Water fog, dry chemical, foam or CO2
Special Firefighting Procedure: Burning will produce toxic fumes. Wear self-contained breathing apparatus and full turnout gear to fight fire. Avoid spreading liquid and fire by water flooding.
Unusual Fire Hazard: Exposure to heat builds up pressure in closed containers. Cool with water spray.

 

5. REACTIVITY DATA
   
Thermal Stability: Stable
Materials to Avoid: Strong oxidizers
Hazardous Polymerization: Will not occur
Hazardous Decomposition Products: Burning will produce toxic fumes

 

6. HEALTH HAZARD DATA
   
Exposure Limits: Not Applicable
Effects of Overexposure: Low oral and dermal toxicity. Prolonged or repeated exposure may cause irritation, nausea and vomiting

 

7.  PHYSIOLOGICAL EFFECTS SUMMARY
 
Acute:
Eyes: Believed to be minimally irritating
Skin: Believed to be minimally irritating
Respiratory System: Believed to be minimally irritating
Chronic: Not determined
Other: None

 

8.   PRECAUTIONS FOR SAFE HANDLING
 
For general personal hygiene, wash hands thoroughly after handling material. Avoid contact with skin and eyes.

 

9.   PROTECTION AND CONTROL MEASURES
   
Protective Equipment: Impermeable gloves, splash goggles, eye wash and safety shower
Respiratory Protection: If overheated, use approved respiratory protective equipment
Ventilation: Local exhaust and mechanical recommended

 

10.  EMERGENCY AND FIRST AID PROCEDURES
   
Eye Contact: Flush eyes with water for 15 minutes. Call a physician if irritation develops.
Skin Contact: Wash skin with soap and water
Inhalation: Remove to fresh air. Give artificial respiration or oxygen if necessary
Ingestion: First aid not normally required. If uncomfortable, call physician

 

11.  NOTES
NPCA/HMIS                     NFPA
Health      Slight                              Slight
Flammabaility      Slight                              Slight
Reactivity    Minimal                          Minimal

 

12.  SPILL AND DISPOSAL PROCEDURES
 
Environmental Impact: Report spills as required to appropriate authorities. U.S. Coast Guard regulations require immediate reporting of spills that could reach any waterway including intermittent dry creeks. Report spill to Coast Guard Toll Free Number 800-424-8802. In case of accident or road spill, notify Chemtrec 800-424-9300.

Procedures if Material is Released or Spilled: Absorb on fire retardant treated sawdust, diatomaceous earth, etc. Shovel up and dispose of at an appropriate waste disposal facility in accordance with current applicable laws and regulations, and product characteristics at time of disposal.

Waste Management: Dispose of according to Federal, State and Local regulations.

Toxic Substance Inventory Control Act: All components are included on the TSCA Inventory and are in compliance with the TSCA.

For additional information contact:

Summit Industrial Products, Inc.
P.O. Box 131359
Tyler, Texas  75713
903-534-8021

Information given herein is offered in good faith as accurate, but without guarantee. Conditions of use and suitability of the product for particular uses are beyond our control. All risks of use of the product are therefore assumed by the user and we expressly disclaim all warranties of every kind and nature, including warranties of merchantability and fitness for a particular purpose in respect to the use or suitability of the product. Nothing is intended as a recommendation for uses which infringe valid patents or as extending license under valid patents. Appropriate warnings and safe handling procedures should be provided to handlers and users.

 

13.  PREPARATION DATE
 
Revised:  06/12/2003        Supersedes: 06/15/00

 