| 1. IDENTIFICATION |
| |
| Product Identifier: |
Citrosqueeze Turnout Gear Cleaner |
| Product Description: |
Water based cleaner and solvent |
| Manufacturer: |
Toro Sales Inc.
Unit 13, 1080 Cliveden Ave.
Delta, British Columbia, Canada V3M 6G6
24 hr. Emergency Contact: CANUTEC 613-996-6666
Phone: 604-521-3645 (general calls) |
| |
| 2. HAZARDOUS INGREDIENTS |
| |
|
%(W/W) |
CAS Number |
ACGIH, TLV-TWA, TLA-STEL |
OSHA PEL_TWS |
|
|
| d-Limonene |
- |
5989-27-5 |
Not established |
Not established |
| 2-butoxyethanol |
- |
111-76-2 |
25 ppm (skin), N.E. |
50 ppm |
| |
| 3. PHYSICAL DATA |
| |
| Physical State: |
Liquid |
| Odour/Appearance: |
Thin opaque liquid with strong citrus odour |
| Odour Threshold (ppm): |
Not established |
| Vapour Pressure (mm Hg): |
Not established |
| Vapour Density: |
>1 |
| Evaporation Rate: |
<1 |
| Boiling Point: |
196°F |
| Freezing Point: |
32°F |
| pH: |
8.5 |
| Specific Gravity: |
0.98 |
| Solubility: |
Completely soluble in water |
| |
| 4. FIRE/EXPLOSION DATA |
| |
| Flammability: |
Yes |
| Under Which Conditions: |
Vapour may flash in extreme conditions. |
| Means of Extinction: |
Use dry chemical, carbon dioxide or alcohol foam |
| Special Procedures: |
Use water spay to cool containers below the flash point or to
disperse vapour. Fire crews should wear self-contained breathing apparatus. |
| Flash Point/Method: |
None to boiling point |
| Upper Flammable Limit: |
Not established |
| Lower Flammable Limit: |
Not established |
| Autoignition Temp: |
711F° |
| Hazardous Combustion Products: |
Oxides of carbon |
| Sensitivity to Impact: |
No |
| Sensitivity to Static Discharge: |
No |
| |
| 5. REACTIVITY DATA |
| |
| Chemical Stability: |
Normally stable. May oxidize under prolonged exposure to air.
Hazardous polymerization does not occur. |
Incompatibility with
Other Substances: |
Avoid strong oxidizing agents due to increased risk of fire or
explosion. |
Reactivity Under What
Conditions: |
Not reactive under normal conditions. |
| Hazardous Decomposition Products: |
None reported. |
| |
| 6. TOXICOLOGICAL PROPERTIES |
| |
| Route of Entry: |
Eye: major; Skin: major; Ingestion: minor |
| Effects of Acute Exposure: |
Irritation can result from liquid, mist or vapour contact
respiratory tract, eyes and skin. Absorption through skin or inhalation of
vapour at normal temperatures poses minimal hazard. Slightly toxic by ingestion,
but ingestion of large amounts will cause diarrhea. Aspiration can damage lungs
and cause death. |
| Effects of Chronic Exposure: |
Prolonged or repeated exposure can defat skin and lead to
dermatitis. May cause allergic skin response in some persons. Intense long-term
exposure may cause kidney problems |
| Exposure Limits: |
ACGHI-TLV-TWA is 25 ppm for 2-but oxyethanol. "Skin"
notation |
| Irritancy of Product: |
As above |
| Sensitization to Product: |
d-Limonene is a sensitizer |
| Carcinogenicity: |
Not reported by OSH, IARC, NTP, ACGIH |
| Teratogenicity: |
Not reported |
| Reproductive Toxicity: |
Not reported |
| Mutagenicity: |
Not reported |
| Synergistic Products: |
Not reported |
| |
| 7. PREVENTIVE MEASURES |
| |
| Gloves: |
Neoprene, Nitrile, Butyl rubber or Polyvinyl alcohol are
recommended. |
| Respirator: |
No respiratory protection is required under normal conditions of
use. Consider the use of respiratory protection in confined spaces or at
elevated temperatures. |
| Eye: |
Chemical safety goggles recommended. A face shield may be
warranted in some applications. |
| Footwear: |
Impervious boots using same materials as for gloves. |
| Clothing: |
Coveralls or other suitable protective clothing. |
| Other: |
Emergency eye-wash and shower should be available. |
| Engineering Controls: |
Mechanical ventilation, both dilution and local exhaust may be
utilized to keep exposure below the exposure limit. Extra ventilation should be
provided in enclosed spaces and in hot weather. |
| Leak & Spill Procedure: |
Soak up small spills with absorbent materials. Prevent run-off
from reaching sewers, storm drains or natural water bodies. No reportable
quantity according to 40 CFR 302. |
| Waste Disposal: |
Dispose of according to federal, state and local laws. |
| Handling Procedures: |
Avoid generating mists. Keep containers closed when not in use.
Do not freeze. Ground containers to avoid static accumulation. |
| Storage Requirements: |
Empty containers may contain a hazardous residue. Store in cool,
well ventilated area away from incompatible materials and ignition sources. |
| Special Shipping Info: |
Combustible liquid, non-regulated as packaged USA D.O.T.
TDG. UN Number: 16 CFR 172.101 |
|
| 8. FIRST AID MEASURES |
| |
| Specific Measures: |
|
| Inhalation: |
Remove victim to fresh air. If breathing has stopped, a trained
person should perform artificial respiration. Seek medical care. |
| Ingestion: |
Do not induce vomiting. If conscious, give victim 2 glasses of cold water.
Never give anything by mouth to an unconscious person. Seek medical attention. |
| Eye Contact: |
Flush eye for 15 minutes, by the clock, with water while retracting eyelids.
Seek medical attention. |
| Skin Contact: |
Remove contaminated clothing. Wash affected area with soap and
water. Launder clothing before reuse. Seek medical attention if irritation
persists. |
| |
| 9. PREPARATION & DATE |
| |
| Prepared by: |
Kel-Ex Agencies Ltd. with information supplied by Toro Sales
Inc. |
| Phone Number: |
604-986-4617 |
| Date: |
March 5, 2001 |
| |
|
|
Back to Top
 |