EJECTOR FANS

Go Back

EFi50xx Specifications


PRODUCT SPECIFICATION SHEET
Description: 16"/40cm ½ hp Haz.Loc. Blower - Select 115V or 230V
16" Adapter included
Summary: Intrinsically safe motor enclosed in rugged, chemically-resistant, glass-reinforced ABS housing. Metal motor carrier and IP65 switch enclosure. Cast aluminum impeller and reversible duct adapter switches for suction or discharge. High capacity, low head flow. Use with 16" duct.
Fan: 16"(400) x 21 blade
Fan RPM: 1760
Unit Weight: 66 lbs.(30kg)
Dimensions: 19"h x 18"w x 12"d (480mm x 460mm x 305mm)
Noise: 95dB
Motor Type: Electric
Motor Cert: UL rated Class I Group D, UL Class II Group E,F,G
Voltage: 115/230 VAC
Phase:
Frequency (Hz) 50/60
Running Amps: 115V-6.3A/230V-3.1A
Starting Amps: 115V-21A/23V-10A
Horsepower: ½
Airflow Data: Ducted blowers are tested with the duct size and length specified. One and then two 90" turns are placed into the duct to introduce real world conditions. Free air is the airflow without any duct attached. 15ft.=4.6m, 25 ft=7.6m

Duct Size: 16"/40cm
  Free Air 15ft. Straight 15ft. 1-90" 15ft. 2-90" 25ft. 1-90" 25ft. 2-90"
CFM 2720 2018 1644 1356 - -
M3/Hr 4624 3431 2795 2305 - -

Back to Top
Click here to go to WFR's Home Page