BREATHING
Fills from Storage
Instructions:
  1. Select the type of BA cylinder to be filled from top of the chart.
  2. Find the fill method and desired number of storage vessels in the left column.
  3. Select the starting pressure of DOT storage, either 5000 or 6000 psi.
  4. Intersect the cylinder type with the number of storage vessels to determine number of cylinder fills and RF. Residual Factor (RF) represents residual storage volume which may be utilized in conjunction with a compressor to fill BA cylinders when storage pressure alone is insufficient to fill the cylinders to capacity. By adding compressor cylinders filled per hour, cylinders filled from storage, and RF the maximum number of cylinders filled from a complete air system may be determined.
  1. Fills from 70-66HC DOT Cylinders


    2216 PSI
    45 CF
    4500 PSI
    45 CF
    4500 PSI
    88 CF
    2250 PSI
    72 CF
    3000 PSI
    80 CF
    Fill
    Method/Vessel
    Start
    PSI
    Fills RF Fills RF Fills RF Fills RF Fills RF
    Bulk 1 5000 6 4 1 9 1 4 4 2 3 3
      6000 8 3 3 8 2 4 5 2 4 3
    Bulk 2 5000 12 7 2 17 2 8 7 5 5 6
      6000 15 7 6 16 3 9 9 5 7 6
    Bulk 3 5000 17 11 3 25 2 13 11 7 7 9
      6000 22 10 9 23 5 12 14 6 10 8
    Bulk 4 5000 23 14 4 33 3 16 14 9 9 12
      6000 29 13 12 30 6 16 18 9 13 11
    Bulk 6 5000 34 21 6 49 4 25 21 14 14 17
      6000 43 20 18 45 9 24 27 13 20 16
    Bulk 8 5000 45 28 8 65 5 33 28 18 19 22
      6000 58 26 23 61 12 31 36 17 26 22
    Cascade 2 5000 15 4 5 13 2 8 9 3 5 4
      6000 18 4 8 12 4 6 11 3 9 3
    Cascade 3 5000 25 4 9 17 4 10 15 3 8 4
      6000 30 4 15 13 7 7 18 2 14 4
    Cascade 4 5000 35 4 15 19 7 10 21 3 11 5
      6000 42 4 22 15 10 8 25 2 20 3
    Cascade 6 (4 Banks) 5000 53 5 23 29 1 16 32 3 17 8
      6000 62 4 34 22 17 11 39 2 31 4
    Cascade 8 (4 Banks) 5000 72 8 32 37 15 20 44 5 24 9
      6000 87 8 46 29 22 16 52 5 42 6

    Back to Top