FEATURES
- Designed for Class B foams exclusively
- Electronic digital foam proportioning system improves responsiveness, reliability, and accuracy through a range of 75 psi to 250 psi
- On-demand design ensures no foam is bypassed back to the foam tank or re-circulated through the foam pump
- Clean-up is easy because each discharge outlet features its own metering valve. The operator needs only to flush the discharge lines used
- Flexible foam pump drive systems are engineered to run from either a pump transmission or PTO system, depending on customer needs. With the PTO-driven system, foam transfer operations are easy because there is no need to engage the water pump during foam discharge
- Foam systems are capable of using the vehicle's water tank, high-pressure hydrant or draft as a water source
- Foam systems can draft foam concentrate from an outside source, allowing extended foam operation
- Uses a lower electrical load, helping to create a lower-cost system that requires less power from the chassis, and prevents overloading during tough fire calls. Husky is the only municipal-market foam system with this feature.
| Foam Concentrate |
0.2% |
0.5% |
1% |
3% |
6% |
| Husky 30 GPM(L/min) |
3,000 (11,355)* |
3,000 (11,355)* |
3,000 (11,355)* |
1,000 (3,785) |
500 (1,892) |
| Husky 160 GPM(L/min) |
N/A |
N/A |
5,200 (19,682)* |
4,103 (15,529) |
2,286 (8,652) |
| Husky 300 GPM(L/min) |
N/A |
N/A |
5,200 (19,682)* |
5,200 (19,682)* |
4,286 (16,222) |
| *Maximum flow depends on plumbing restrictions |